2025/01/02

OBDSTAR OdoMaster Renault Cluster RH850 Black Screen Solution

 Problem:

It is a Dacia Duster instrument cluster with RH850 processor R7F10400. After mileage correction by OBDSTAR Odomaster via OBD, the dashboard went black, I can write backup via obd but same problem always black screen.

OBDSTAR OdoMaster Renault Cluster RH850 Black Screen 1

OBDSTAR OdoMaster Renault Cluster RH850 Black Screen 2

OBDSTAR OdoMaster Renault Cluster RH850 Black Screen 3

OBDSTAR OdoMaster Renault Cluster RH850 Black Screen 4


Some others may have the same problem with the Renault Master dashboard with a micro RH850. After writing the flash, the dashboard turned off and has no communication.

 

 

Solution:

First read what you have on processor (for backup), and after that write the flash that obdstar has read.

Some users have managed to solve the problem with Xtool Pl.

Here is the wiring diagram for Xtool (Polish device).

Renault Cluster RH850 pinout xtool


Read the instructions that you have on xtool, the order on write.

There are 2 blue pin. No need to split pin.  You have the wiring connection on smok jtag (colours are the same on jtag and xtool), Use the same blue to elongate the wire.

The dash work after flash original file via xtool pinout.

 

SMOK will recover this cluster as well.

Renault Cluster RH850 pinout smok 1

Renault Master Dashboard R7F10400 Recovery with SMOK by Jtag

Remember write only FLASH!!! Don’t touch Dataflash.
After write dash is back to original state.

Renault Cluster RH850 pinout smok 2

No comments:

Post a Comment

Note: Only a member of this blog may post a comment.